5
1. Run (18-gage minimum) low-voltage wiring from controller to heater.
2. Locate microprocessor PC board inside heat pump electrical controls enclosure
(See Figure-1A on Page-3).
3. Connect wiring from external controller’s low-voltage heater control terminals to heat pump microproces-
sor board options terminal block; use terminals: “Y” and “Z” (See Figure-2A).
4. Reestablish electrical power and water flow to heater.
5. Turn “POOL” thermostat to
OFF position by pressing and holding the “DOWN” key on heater control
panel (set temperature below 60-degrees). Then press “POOL/SPA” key once to select SPA thermostat.
Set SPA thermostat to OFF position by pressing and holding “DOWN” key on heater control panel (set
temperature below 60-degrees).
6. Simultaneously press and hold “UP” and “Down” keys until “CF1” is displayed.
7. While “CF1” is displayed, press POOL/SPA key repeatedly until “LOC” is displayed. Now press “UP” key,
repeatedly, until “050” is displayed.
8. Press POOL/SPA key repeatedly until “JAO” is displayed. Press “UP” key repeatedly until “2” is dis-
played. WAIT... press no other buttons/keys.
9. After a delay of approximately 25-seconds, water temperature will display. The external controller-to-
heater interface is now ready to test and operate.
Microprocessor-Controlled (Digital) Heat Pumps: 2-Wire Connection
(See Figure-2A)
FIGURE-2AFIGURE-2
2-WIRE
DIAGRAMS
INTERFACE METHOD #2
Controllers Using a 3-Wire Connection to Heat Pump
(C-D-E OR FS-2 TERMINALS)
CONTROLLERS NOT EQUIPPED WITH OWN THERMOSTATS.
(THESE CONTROLLERS SIMPLY SELECT THE HEATER’S THERMOSTATS)
SEE NEXT PAGE FOR STEPS TO BE FOLLOWED FOR INTERFACE METHOD #2
Intermatic
”Air Force”
Series
Controllers
Air Touch
Controllers
Universal
Controller by
AquaCal
Pentair/Compool
all “Easy Touch”
Series
Jandy
AquaSwitch
Compool
CP30
CP100T